1-800-SENSOR2, FAX: 630-377-6495 diagrams. AT AN ANGLE ON THE Subscirbe to specific System Sensor email communications. Fill out our feedback form! It sounds like a short problem somewhere in the smoke lines to me, but I am not sure. Fill out our feedback form! To view our listings, please visit one of the following sites. At a minimum, cleaning should be performed annually. For the effect of polar distribution (rated candela at each angle), the ANSI/UL 1971 minimum percentages are used for the calculations. 12/24 I have a DSC alarm system that my current System Sensors are connected to and would I need to do anything special when I replace the old with the new other then reset the system? 9H2u*A^Xob`bd`SD+0 vEw
item 8 System Sensor 2W-B i3 Series 2-wire, Photoelectric Smoke Detector, 5.0 out of 5 stars based on 9 product ratings. After phoning System Sensors toll free number 800-SENSOR2 (736-7672) for a Return Ensure proper wiring and power is applied. ld house alarm system. Trending price is based on prices over last 90 days. Turn on: 1. item 1 System Sensor 2W-B i3 Series 2-wire, Photoelectric Smoke Detector. \kUb5{,P'Zwd**4C8X)z
0.3 sec Air conditioners, heaters, fans, and fresh air intakes and returns can drive smoke away from the detector. fasteners. 3825 Ohio Avenue
$156.00. No Contract Alarm Monitoring starting at $10 a month! 1. Activate the light at the display. REMOVABLE System Sensor is not selling, supporting or endorsing AFMGs EASE Evac voice evacuation software. Improper connections can prevent a system from responding properly in the event of a fire. Whenever an alarm is detected by the System Sensor 2W-B, the smoke detector will show a solid red LED. System Sensor is pleased to provide this Strobe Coverage Calculator, formerly known as Equivalent Facilitation Calculator. The i3 Series detectors include a tamper-resistant feature that prevents removal from the mounting base without the use of a tool. The heads and bases are clearly identified as either 2-wire or 4-wire. 3. covers from any detectors that were left in place during construction. Wired. Two-wire Fill out the form and we'll contact you shortly. PipeIQ guides users through the initial pipe layout and system configuration for a FAAST aspiration system. Observe the LEDs on each detector: COVER. The System Sensor 2W-B is a 2-wire smoke detector and a member of System Sensors i3 Series of photoelectric smoke detectors. Wd]_c'F1p% In order for this feature to work properly, the chamber must never be opened while power is applied to the smoke Max. Installation of the 2W-B, 2WT-B, 4W-B, and 4WT-B detectors is simplified by the use of a mounting base that may be pre-wired to the system, allowing the detector to be easily installed or removed. The 2W-MOD can indicate a need for cleaning, replacement, or a freeze condition (2WT-B only) at the control, Installation of the 2W-B, 2WT-B, 4W-B, and 4WT-B detectors is, simplified by the use of a mounting base that may be pre-wired, to the system, allowing the detector to be easily installed or, removed. The screw terminals in the mounting base will accept 1422 gauge wire. We offer conventional and intelligent products for smoke detection, heat detection, fire and CO combination detection, and multi-criteria / multi-sensor detection, as well as bases and accessories. from the end of the feed wire, inserting it into the proper base terminal, and 50 A average Mounting w responsible for an unreported house fire. The screw terminals in the mounting base will accept 1422 gauge wire. which provides detailed information on detector spacing, placement, zoning, wiring, and special applications. 1050 0 obj
<>stream
FCC Statement I am very happy with the purchase and while I only needed one I bought 2 to have one in reserve. The 2W -MOD2 can. Honeywell's Esser brings Optical smoke detectors ES Detect which have ability . All models incorporate a state-of-the-art optical sensing chamber and an advanced microprocessor. indicate a need for cleaning, replacement, or a fr eeze condition (2WT -B only) at the control panel or module. Wiring Installation Guidelines The Companys obligation We are notifying you about EASE Evac as a service to our customers as it may simplify voice evacuation design. For best system performance, all wiring should be installed in separate grounded conduit; do not mix fire alarm system wiring in the same conduit as any other electrical wiring. Disable the zone Developed and delivered by Honeywell industry experts, HBU training employs techniques and technologies to help your teams learn everything they can about our products. and service during the three year period commencing with the date of manufacture. Proper wire gauges should be used. The 2W-B smoke detector consists of a mounting base that can be mounted on a single gang box, a three and a half or four inch octagonal box or a four inch square box with a plaster ring. 100 8.5 8.5 Volts Explore System Sensor products including: AV Notification, Beam Smoke detection, CO detection, HVAC Smoke detection, spot smoke detection, relays, & modules. on the screen/sensing chamber with the arrow on the housing. System Sensor products are designed and manufactured to meet or exceed various product safety and certification requirements. SWITCH WITH A In wet or excessively humid areas, or next to bathrooms with showers. applicable state and local codes, and any special requirements of the local When performing maintenance on your smoke detector, simply turn the 2W-B head counter clockwise to remove it from the base. Figure 3a: Wiring Diagram, 2W-B and 2WT-B. Normal (standby) Heat Sensor (Model 2WT-B and 4WT-B): 135F (57.2C) Freeze Trouble (Model 2WT-B and 4WT-B): 41F (5C) Operating Temperature Range: 2W-B and 4W-B: 32 to 120F (0 to 49C) 2WT-B and 4WT-B: 32 to 100F (0 to 37.8C) Operating Humidity Range: 0 to 95% RH non-condensing Storage Temperature Range: -4 to 158F (-20 to 70C) Diameter (including base): of manufacture. System Sensors intelligent and conventional modules are designed to help you meet a wide range of application requirements. System Sensor BK-2WB Photoelectric i3 Series Smoke Detector, 2-Wire, White Brand: System Sensor ADI #:BK-2WB Model #: 2W-B Name: System Sensor BK-2WB Photoelectric i3 Series Smoke Detector, 2-Wire, White Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Product Overview Installation ease. The CLSS Tool Suite allows you to perform battery, voltage drop, and Db line loss calculations in a single desktop application. After power-up has completed and the detector is functioning normally within its listed sensitivity range, the green LED blinks once every five seconds. 21. The System Sensor 2W-B is a 2-wire smoke detector and a member of System Sensors i3 Series of photoelectric smoke detectors. 32 to 120F (0 to 49C) Models 2WT-B and 4WT-B also feature a restorable, built-in, fixed temperature unit. When I put the system in alarm mode and set it off, the panels still have the same behavior and the sirens (not the keypad alarm) do not sound. Two LEDs on the detector provide a local visual indication of the detectors status: After an initial power-up delay, the red and green LEDs will blink synchronously once every ten seconds. Make sure to observe polarity when wiring up your smoke detectors and you should connect an end-of-line resistor across the loop wires at the last 2W-B on your loop. Near fresh air inlets or returns or excessively drafty areas. This includes cleaning, maintenance or screen replacement. current list of detectors and UL Listed compatible control units. It will take approximately 80 seconds for the detector to finish the power-up cycle (see Table 2). HOTFire is a free online site that helps users quickly plan and model notification appliance circuits (NACs) using the entire line of SpectrAlert Advance and L-Series. The LED indication must not maintenance or screen replacement. *Assumes the panels alarm verification reset time is 10 seconds or less. Red. The i3 Series heads and bases are keyed so that a 2-wire head will only mount to a 2-wire base, and a 4-wire head will only mount to a 4-wire base. MFR PART # 2W-B SYSTEM SENSOR | 2W-B i3 Series Detector, 2-wire, 12/24 V DC, with Base MFR PART # 2W-B PART # 674092 Spec Sheet Email Print Minimum 1 Each In Stock Details References Shipping Description Installation ease. When returning the system to service, be sure to remove the dust Each zone provides only enough alarm current (20ma) to power one smoke in alarmed state. F System Sensor's AV notification devices are one of the most versatile, easy to install, and cohesive audible visual (AV) notification appliances in the industry. The detector will drop When used with an i3 Series compatible control panel or the i3 Series 2WMOD module (refer to installation manual D500-46-00), the 2W-B and 2WT-B Reorient or relocate the receiving antenna. visual status indication at each detector. The LED indication must not, be used in lieu of the tests specified under Testing. 4-Wire Smoke Detector with 135F Fixed Heat Sensor, 2-Wire Smoke Detector with Fixed Heat Sensor, System Sensor 2W-B, 2WT-B, 4W-B & 4WT-B - Installation Guide. I have since replaced the battery, which has resolved the smoke error. System Sensor 2WTA-B I3 Series 4-Wire Conventional Photoelectric and 135F Fixed Temperature Thermal Detector with Built-in Sounder, 85 dB Sounder, Form C Relay, Isolated Thermal Sensor. I have a Vista 6150 15P Control Panel and an old System Sensor 2312/24TB 4 wire Smoke/heat detector. I will say that it came packaged correctly and it functions as designed, would buy again. 3. gently blow the smoke through the detector until it alarms. Alarm Verification* Ready to learn more? All System Sensor i3 Series smoke detectors are designed for easy installation, advanced detection and fast inspection. We're here to provide technical support for System Sensor products and service. Please read thoroughly System Sensor manual A05-1003, Applications Guide for System Smoke Detectors, which provides, detailed information on detector spacing, placement, zoning, wir-, ing, and special applications. Copyright 2023 Honeywell International Inc. View a list of all System Sensor locations worldwide. to the plastic. Therefore, the only NOTICE: This manual shall be left with the owner/user of this equipment. Operating Temperature Range: or damage is caused by the Companys negligence or fault. 1o)!2'1hg'0?,s1e*F 6S(Ft50
AKTX"897cOF
7 Weight: the 2W-MOD2 installation manual, document D500-4600, for Style D wiring 1000 0 obj
<>
endobj
In fact, the 2W-B is a System Sensor i3 series intelligent . Once the mounting base is installed, the 2W-B smoke detector attaches to the base by simply inserting the head and turning it clockwise until it locks in place. Should it become necessary, the screen/sensing chamber is field replaceable. Follow the steps in the Tech Bulletin below to check your current firmware version and update your device firmware if needed.. such as kitchens; in garages (vehicle exhaust); near furnaces, hot water detector to be easily installed or removed. Unfortunately we do not support fire panels like the 32FB. Models 2WT-B and 4WT-B also feature a restorable, built-in, fixed temperature (135F) thermal detector and are also capable of sensing a freeze condition if the temperature is below 41F. NFPA 72 requirements. the incorporation of features compatible with drywall fasteners. Twisted pair may be used to provide additional protection against extraneous electrical interference. Multi-voltage conventional relays are used for high-current switching applications, such as fan and damper assembly control, door control, air handling unit controls, and other building system interfaces. The smoke alarm was perfectly compatible with my 24-year old house alarm system. Compatible with 12- or 24-volt systems. 2WTA-B, or 2WTR-B) on Style D IDCs is to use a 2W-MOD2 module. Product specifications subject to change without notice. They were an easy mount adapted to our smoke detecting system. 4.Direct mount or to ceiling using drywall fasteners (Figure 2). Any advice/help would be greatly appreciated. Start-up Capacitance: Smoke Alarm. DSC NEO: System Sensor 2-wire smoke wiring and programming This video showcases the wiring and programming for 2-wire smokes on a DSC NEO security system. See how you can simplify specification, configuration, and installation of your notification project - saving time and money in the process. The Company shall not This feature ensures that your security system will not experience nuisance false alarms. 2. 45 Compatible with SENS-RDR sensitivity tester; Full agency compliance with UL 268 and UL 2075; Technical Specifications: System Voltage: 12/24 VDC; "), INSTALLATION AND MAINTENANCE INSTRUCTIONS, 3825 Ohio Avenue, St. Charles, Illinois 60174. switch opening; push and hold. Series detectors are designed to provide open area protec-, tion. Should I still get the "shorted out keypad". 0
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. optional Model RA400Z Remote Annunciator to be connected. Subscirbe to specific System Sensor email communications. To view this information, simply choose a manufacturer and the appropriate model. to 35 max. Our hardwired CO detectors with RealTest use electrochemical sensors to measure carbon monoxide levels and alert residents with a flashing Temp-4 signal alarm. I would like to replace it with similar 4 wire detector like the 4WT-B detector and wanted to check if they are compatible? Installation of the 2W -B, 2WT -B, 4W -B, and 4WT -B detectors is simplified . Copies of this The 2W-MOD2 installation manual may be downloaded from the Should it become necessary, the screen/sensing chamber is field replaceable. However, the i3 Series smoke detector allows for fast and easy inspection. Just fill out the form and click your area of interest. contaminants settling in its chamber. 4 to 158F (20 to 70C) To test this please remove AC power and set the panel into alarm mode to see if the battery will support the system and report back. conduit; do not mix fire alarm system wiring in the same conduit as any other detector is in need of maintenance because its sensitivity has shifted outside 2W-B Datasheet (PDF) - Systemsensor advanced ideas. 6. or exclusion may not apply to you. (if excessive electrical noise is present) B401B / B406B / B110LP / B116LP A 120 System Sensor 2800 A Photo N/A N/A 120 System Sensor 2800TH A Photo / Therm. %PDF-1.6
%
Compatible Brand. 0 to 95% RH non-condensing MOD2 module (refer to installation manual D5 00-46-00), the 2W -B and 2WT -B. are capable of gener ating a "maintenance needed" signal. System Sensor webinars provide relevant and timely information on products, market trends, and legislation. The mounting base installation is further simplified by. has been made tamper resistant, use a small screwdriver to depress the square Please read thoroughly System Sensor manual A05-1003, Applications Guide 4. Power must be removed from the detector Hold a smoldering punk stick or cotton wick at the side of the detector and Two-wire models must be used with compatible UL Listed panels only. 3825 Ohio Avenue, St. Charles, Illinois 60174 Each zone provides enough stand by current (2ma) to power up to sixteen smoke detectors. Page 2 System Sensor two-wire smoke detectors are marked with a compatibility identifier located on the label on the back of the product. Save 6% at checkout. Peak Standby Current: Detectors may remain in operation provided they continue to pass the regular testing. identifier located on the label on the back of the product. The microprocessor allows the detector to automatically adjust its sensitivity back to the factory setting when it becomes more sensitive due to contaminants settling in its chamber. The i3 line redefines installation ease with its plug-in design. Two LEDs on the detector provide a local visual indication of the detectors status: IMPORTANT: This detector must be tested and maintained regularly following System Sensor tools include a variety of software, drawings and calculators to help you effectively plan and prepare for your next fire safety system installation. Initial LEDStatus Indication A copy of this list is available from System Sensor upon request. This latest software also includes an enhanced interface for increased ease of use. To measure the detectors sensitivity, the i3 Series Model SENS-RDR Infrared Place detector on the base and rotate clockwise. =&5~9KY!m}oC%IF# V. No Contract Alarm Monitoring starting at $10 a month! models must be used with compatible UL Listed panels only. Deciding Whether to Use 2-Wire or 4-Wire Smoke Detectors. All wiring must be installed in compliance with the National Electrical Code, applicable state and local codes, and any special requirements of the local Authority Having Jurisdiction. I am not of the exact model number of the existing 2-wire smoke detector so I cannot say for sure if the back plates are the same.